Wacker Neuson Flameless Indirect-Fired Air Heaters

Please Request a Quote for Pricing

Product Information

All the heat without a flame!

Axiom Equipment Group’s Flameless Indirect-Fired Air Heaters are ideal for potentially volatile applications where “no open flame” is a requirement.

Engine driven, these heaters develop very high CFM and static pressure to maximize your heat delivery. Both models feature positive air and high temperature shutdowns and offer simple one button operation for a rental friendly design.

Industry applications which require no flame include Oil & Gas Exploration, Mining, Construction and Restoration Industries.

All of our Flameless Indirect-Fired Air Heaters include additional features such as

  • Spill containment of all engine oil/coolant and mineral oil fluid for environmental friendliness
  • Performance-monitoring strobe lights which indicate from a distance that systems are/are not operating properly
  • Sealed alternator for longer service life
  • Lock Out/Tag Out approved master switch for added operator safety

 

Technical Data HIF 690 HIF 1200
Dimensions (L x W x H) in (mm) 148 x 66 x 78 (3,759 x 1,676 x 1,981) 168 x 68 x 66 (4,267 x 1,727 x 1,676)
Approximate Weight (w/out fuel) lbs (kg) 3,020 (1,370) 4,300 (1,951)
Approximate Weight (with fuel) lbs (kg) 3,720 (1,687) 5,770 (2,617)
Fuel Tank Capacity gal (l) 100 (378.5) 210 (795)
Fuel Type Diesel #2 Diesel #2
Engine Type Cummins 4B3.3 Tier IV i John Deere 6068 Tier III
Air Outlets 12″ dia qty
20″ dia qty
2
1
4
2
Air Returns 20″ dia qty 1 1
Performance
Sizing Air-Heat ft 3 (m 3) up to 1,000,000 (28,300) up to 1,700,000 (48,000)
Maximum Input Btu/hr (kW) 686,000 (200) 1,204,000 (353)
Maximum Air Output Temperature F (C) 250 (120) 250 (120)
Max Temperature Rise* F (C) up to 150 (83) up to 150 (83)
Fuel Consumption gph (lph) 4.9 (18.5) 8.6 (32.6)
CFM up to 4,000 up to 6,000
Static Pressure in. water column 3.5 +  4.0 +
*with attached ductwork

  • A Wacker Neuson Product
  • HIF 690: 686,000 Btu/hr at max consumption (4.9 gph diesel).
  • HIF 1200:1.2 Million Btu/hr at max consumption (8.6 gph diesel).
  • Up to 6500 CFM and 4″ Water Column Static Pressure.
  • Automatic louvers help maintain desired temperature.
  • High performance mineral oil fluid to achieve outlet temperature up to 250°F (120°C).
  • Spill containment of all engine oil/coolant and mineral oil fluid for environmental friendliness.
  • Performance monitoring strobe light indicates from a distance that all systems are operating properly.
  • Sealed alternator for longer service life.
  • Lock Out/Tag Out approved master switch for added operator safety.
  • Both models are CSA certified, UL approved and TDG compliant.